简要描述:RETZ (空气)进口蒸汽减压阀为铸钢材质阀体、主阀阀芯、导阀阀芯、阀座、及过滤网等均为不锈钢材质。适用于蒸汽和压缩空气系统。压力调节比可达10:1,控制准确

  • 品牌:RETZ
  • 工况条件:减压
  • 温度/压力:P-T:40bar-285℃
  • 更新时间:2022/08/22
产品详情 在线咨询

(空气)进口蒸汽减压阀 主要技术参数及性能 Main technical parameters and performance进口蒸汽减压阀 主要技术参数及性能.jpg

启动前正常的位置是主阀关闭,而导阀则由弹簧作用力打开.蒸汽由导阀经压力控制管进入主阀隔膜室,部分蒸汽则由控制孔流向下游.施加在主阀隔膜上的控制压力增大,打开主阀  RETZ The normal position before startup is that the main valve is closed, while the pilot valve is opened by the spring force. The steam enters the main valve diaphragm chamber through the pressure control pipe from the pilot valve, and part of the steam flows downstream through the control hole. The control pressure applied to the main valve diaphragm increases, and the main valve is opened


随着蒸汽流过主阀.下游压力上升,并由下游压力感应管反馈作用在导阀隔膜的下部(为了确保下游压力的稳定,应安装下游压力感应管),该作用力使导阀逐渐节流关小,与隔膜上部的弹簧作用力相平衡,从而维持主阀隔膜室内的压力,控制主阀的开度,输送适量的蒸汽,维持下游稳定的压力.当下游压力上升时,反馈压力增大,导阀关闭,主隔膜室的压力从控制孔释放,使主阀紧密关闭 RETZ As the steam flows through the main valve The downstream pressure rises and is fed back to the lower part of the diaphragm of the pilot valve by the downstream pressure sensing pipe (in order to ensure the stability of the downstream pressure, the downstream pressure sensing pipe shall be installed). This force causes the pilot valve to gradually throttle and close down, which is balanced with the spring force on the upper part of the diaphragm, so as to maintain the pressure in the diaphragm chamber of the main valve, control the opening of the main valve, deliver an appropriate amount of steam, and maintain the stable downstream pressure When the downstream pressure rises, the feedback pressure increases, the pilot valve closes, and the pressure of the main diaphragm chamber is released from the control hole to close the main valve tightly

下游任何的负载变化或压力的波动,都会反馈在导阀隔膜的下方,从而调节主阀的开度,确保下游压力的准确稳定 Any load change or pressure fluctuation in the downstream will be fed back to the lower part of the pilot valve diaphragm, so as to adjust the opening of the main valve and ensure the accuracy and stability of the downstream pressure

螺纹连接: 1/2"-2"  BSP NPT

法兰连接:  DN15-250 

执行标准:  BS16/25  GB16/25  DIN16/25  JIS16/25  ANSI 150

阀体承压: PN16-40 

工作温度: 蒸汽 285℃、空气 120℃


压力控制范围 Pressure control range

0.2~3.0 bar g 黄色弹簧

2.5~7.0bar g 蓝色弹簧

6.0~12.0barg 红色弹簧

0.2~17barg 锥形弹簧

16.0~24.0 bar g 灰色弹簧

 

 

 

 

零件名称

零件材料

阀体

中盖

底盖

WCB

A105

CF8

304

CF3

304L

CF8M

316

CF3M

316L

ZG20CrMo

15CrMo

ZG20CrMoV

15CrMo1V

阀座

2Cr13

304

304L

316

316L

304+STL

304+STL

阀瓣

2Cr13

304

304L

316

316L

304+STL

304+STL

缸套

2Cr13/15

(镀硬铬)

304

304L

316

316L

304

304

活塞

2Cr13

304

304L

316

316L

304

304

活塞环

合金铸铁

合金铸铁/

对位聚苯

合金铸铁/

对位聚苯

合金铸铁/

对位聚苯

合金铸铁/

对位聚苯

耐高温

合金铸铁

耐高温

合金铸铁

导阀座

2Cr13

304

304L

316

316L

304+STL

304+STL

导阀杆

2Cr13

304

304L

316

316L

304+STL

304+STL

膜片

1Cr18Ni9Ti

0Cr18Ni9

00Cr19Ni10

0Cr17Ni12Mo2

00Cr17Ni14Mo2

1Cr18Ni9Ti

1Cr18Ni9Ti

主阀弹簧

50CrVA

0Cr18Ni9

00Cr19Ni10

0Cr17Ni12Mo2

00Cr17Ni14Mo2

Inconel-X750

Inconel-X750

导阀弹簧

50CrVA

0Cr18Ni9

00Cr19Ni10

0Cr17Ni12Mo2

00Cr17Ni14Mo2

Inconel-X750

Inconel-X750

调节弹簧

60Si2Mn

60Si2Mn

60Si2Mn

60Si2Mn

60Si2Mn

60Si2Mn

60Si2Mn

适用

工况

适用介质

非腐蚀性

硝酸类

强氧化

醋酸类

醋酸类

非腐蚀性高温介质

适用温度

密封面(X≤80℃ F≤200℃ H≤300℃常规产品)) 特殊订货≤425℃(碳钢)

≤540℃(不锈钢、铬钼钢、铬钼钒钢)


性能特点∶ Performance characteristics

无需外部动力,减少安装费用 No external power is required to reduce installation costs

精确控制制程压力,改善制程效率,提高产品质量 Accurately control the process pressure, improve the process efficiency and improve the product quality

多种控制的组合,减少总的设备投资  Combination of multiple controls to reduce total equipment investment

本质安全,可用于危险区域  Intrinsically safe for use in hazardous areas


(空气)进口蒸汽减压阀流量示意图 Flow diagram

进口蒸汽减压阀 流量示意图.jpg

注: Notes

此流量表是以装上外部感应管为基准的,如不装外部感应管,流量有所减小。在下游压力很低的工况,流量减小可达30%进口蒸汽减压阀.jpgThis flow meter is based on the installation of external induction tube. If the external induction tube is not installed, the flow will be reduced. When the downstream pressure is very low, the flow can be reduced by up to 30%. How to use the chart to saturate the steam


饱和蒸汽  Saturated steam

例;蒸汽流量为600kg/h,压力从6bar减至4bar。在表中找到上游压力为6bar的曲线和下游压力为4bar的交点,从该点垂直身下,找到所有系列口径的容量。在该列中DN32的阀是能满足要求的最小口径阀 Example; The steam flow is 600kg / h and the pressure is reduced from 6bar to 4bar. In the table, find the intersection of the curve with the upstream pressure of 6 bar and the curve with the downstream pressure of 4 bar. From this point, find the capacity of all series of calibers. In this column, DN32 valve is the minimum diameter valve that can meet the requirements


过热蒸汽 Superheated steam

由于过热蒸汽比容较大,图中给出的值应乘以修正系数,若过热度为55℃,则修正系数为0.95,若过热度为100℃,修正系数为0.9,用于上述例子,若蒸汽过热度为55℃,则DN32口径的减压阀流通能力为740X0.95=703kg/h,仍能满足600kg/h的负载要求,则DN32 的阀仍适用 Since the specific capacity of superheated steam is large, the value given in the figure should be multiplied by the correction factor. If the superheat is 55 ℃, the correction factor is 0.95; if the superheat is 100 ℃, the correction factor is 0.9. For the above example, if the superheat is 55 ℃, the flow capacity of the DN32 pressure reducing valve is 740x0.95 = 703kg / h, which can still meet the load requirement of 600kg / h, then the DN32 valve is still applicable


故障排除 Troubleshooting

故障

制造质量的原因

用户方面的原因

相应用户须知

减压阀直通失效

1.装配时不清洁

1.活塞卡住(在最高位置以下)

2.阀瓣或顶杆在导向套内卡住

3.阀瓣弹簧失去弹性

4.导阀泄漏或导阀瓣在孔内卡住

5.密封面间夹有导物或损坏6.膜破损,或其周边泄漏

7.阀后腔至膜片通道堵塞

1.活塞不破裂、气缸磨损应修理;应定期清洗,以免混入异物卡住

2.应及时卸下修理

3.更换弹簧

4.应定期清洗.控制通道应有过滤器

5.损坏的应修理或更换

6.定期换膜.周边密封处泄漏时应重新装配修理。

7.应解体清洗,可设阀前过滤器及排污管

阀门不通

1.装配时不清洁

1.活塞卡死在最高位置,(常见为异物、锈蚀等卡死)

2.阀前腔一导阀,导阀一活塞的小通道堵塞

3.弹簧失效,致使阀瓣不能打开

1.解体清洗和修理

2.应通清洗,通道应设过滤网

3.调整弹簧压紧力

阀后压力调不准

1.活塞密封不严2.装配质量差

1.弹簧疲劳失效

2.弹簧刚度过大

3.活动部件已磨损

4.膜片、薄膜已疲劳失效

1.更换弹簧

2.更换的弹簧应选用正确

3.应解体修理,装配要正确

4.应更换膜片、薄膜


安装示意图 installation diagram

蒸汽减压站 Steam decompression station

蒸汽减压站.jpg

减压站中的减压阀应根据管道上,下游压力和蒸汽流量选择口径大小.一般减压阀最少比上游管道小一个口径,其它管道件如汽水分离器,过滤器,截止阀等应与管道同口径.如有需要,减压站可安装旁通阀以备紧急情况使用,旁路阀应安装在减压阀上方与减压阀同口径  RETZ The diameter of the pressure reducing valve in the pressure reducing station shall be selected according to the upstream and downstream pressure and steam flow of the pipeline Generally, the pressure reducing valve shall be at least one caliber smaller than the upstream pipeline. Other pipeline parts, such as steam water separator, filter and stop valve, shall be of the same caliber as the pipeline If necessary, the pressure reducing station can be equipped with a bypass valve for emergency use. The bypass valve shall be installed above the pressure reducing valve with the same diameter as the pressure reducing valve


减压阀串联 Pressure reducing valve in series

减压阀串联.jpg

如果减压比超过10∶1,应使用2个减压阀串联以获得准确的压力控制 If the pressure reducing ratio exceeds 10:1, 2 pressure reducing valves shall be used in series to obtain accurate pressure control


减压阀并联 Pressure reducing valve (parallel)

减压阀并联.jpg

减压阀可从100%到0%调节负荷尽管如此,如果阀门要经常工作在小负荷工况时,最好用2个较小的减压阀并联,如果小负荷小于最大负荷的10%则最好选用2台减压阀并联  The pressure reducing valve can adjust the load from 100% to 0%. However, if the valve is to work under small load, it is better to use two smaller pressure reducing valves in parallel. If the small load is less than 10% of the maximum load, it is better to use two pressure reducing valves in parallel

并联减压站还用于关键的,不可中断供汽的应用 Parallel pressure reducing stations are also used for critical, uninterrupted steam supply applications