超低温LNG质量流量计
简要描述:RETZ进口超低温LNG质量流量计是测量液化天然气等低温介质而研制的。流量计由质量流量传感器和变送器组成。传感器具有测量精度高、量程比宽、可靠性高等优点
- 品牌:RETZ
- 工况条件:流体测控
- 温度/压力:P-T: 40bar@-200℃
- 更新时间:2023/04/01
进口超低温LNG质量流量计 产品用途 Product use
采用高效的隔热技术有效控制LNG等低温介质在流经传感器时与外界的热交换,降低LNG等低温介质在管路中的气化,从而降低气化对流量计量造成的影响。
Efficient heat insulation technology is used to effectively control the heat exchange between low-temperature media such as LNG and the outside world when flowing through the sensor, reducing the gasification of low-temperature media such as LNG in the pipeline, thereby reducing the impact of gasification on flow measurement
技术参数 Technical parameter
流量测量精度 | 0.1%、0.15%、0.2%、0.5% | 被测介质温度 | -200℃-100℃ |
重复性 | 0.05%-0.1% | 适用环境温度 | -30~70℃ |
密度测量范围 | 0 | 测量管材质 | 316L |
密度测量精度 | ±0.002g/cm3 | 工作压力 | 常规4MPa,高压可特殊订制 |
温度测量范围 | -200-350℃ | 防爆型等级 | Exd[ib]IICT1~T6Gb |
温度测量精度 | ±1℃ | 防护等级 | IP67 |
输出信号 | 4-20mA直流电流信号、0-10KHZ频率脉冲信号、脉冲当量信号、RS485通讯信号 |
参考量程表 Reference Range Table
型号 |
公 称 通 径 | 推荐流量范围(kg/h) | 最大流量范围(kg/h) |
RN-MLG6 | 06 | 0-600 | 0-960 |
RN-MLG15 | 15 | 0-3600 | 0-4500 |
RN-MLG25 | 25 | 0-9600 | 0-12000 |
RN-MLG40 | 40 | 0-30000 | 0-36000 |
RN-MLG50 | 50 | 0-48000 | 0-60000 |
RN-MLG80 | 80 | 0-150000 | 0-180000 |
RN-MLG100 | 100 | 0-240000 | 0-280000 |
科里奥利(科氏力)质量流量计原理 Coriolis mass flowmeter principle
科里奥利质量流量计(Coriolis Mass Flowmeter)简称科氏力质量流量计,一个弯管道的两端被固定,在两个固定点的中间位置给管道施加振动力(按管道的谐振频率),使其以固定点为轴以其自然频率u振动,当管道内没有流体流动时,管道只受外加震动力作用,管道两个半段振动方向相同,没有相位差。当有流体流动时受管道内流动的介质质点科氏力Fc的影响,管道的两个半段按相反的方向发生扭动,产生相位差,这一相位差同质量流量成正比,这就是科氏质量流量计的工作原理.
Coriolis Mass Flowmeter is referred to as Coriolis force mass flowmeter. Both ends of a curved pipe are fixed, and vibration force (based on the resonance frequency of the pipe) is applied to the pipe at the middle of the two fixed points, making it vibrate at its natural frequency u with the fixed point as the axis. When there is no fluid flow in the pipe, the pipe is only subjected to external vibration force, and the vibration directions of the two halves of the pipe are the same, without phase difference. When there is fluid flowing, influenced by the Coriolis force Fc of the medium particles flowing in the pipe, the two halves of the pipe twist in opposite directions, resulting in a phase difference that is proportional to the mass flow rate. This is the working principle of a Coriolis mass flowmeter
安装外形尺寸 Installation overall dimensions
三角形分体式
规 格 | A(法兰间距)mm | B(整体高度)mm | C(外壳厚度)mm |
6 | 161 | 319 | 235 |
15 | 188 | 339 | 293 |
25 | 210 | 539 | 448 |
40 | 262 | 636 | 576 |
U型分体式
规格 | A(法兰间距)mm | B(整体高度)mm | C(外壳厚度)mm |
50 | 552 | 711 | 506 |
80 | 731 | 893 | 653 |
100 | 755 | 1162 | 709 |